07971189853
sales@ventilair.in
Boiler IDs Fan
Boiler IDs Fan

Boiler IDs Fan

Price 125000 INR/ Unit

MOQ : 1 Unit

Boiler IDs Fan Specification

  • Air Volume
  • 2000-40000 m3/hr (Customized)
  • Speed
  • 960-2900 RPM
  • Power Consumption
  • Depends on Model and Capacity
  • Power
  • 3-150 kW (Customized Depending on Model)
  • Revolution
  • Single/Double as per Requirement
  • Voltage
  • 415 Volt (v)
  • Pressure
  • 100-2000 mmWG (Millimeter Water Gauge)
  • Noise Level
  • Below 85 dB
  • Usage
  • Industrial
  • Product Type
  • Other
  • Type of Fan
  • Induced Draft (ID) Fan
  • Power Mode
  • Electric
  • Installation Type
  • Floor Mounted
  • Blade Material
  • Mild Steel or Stainless Steel
  • Shape
  • Centrifugal, Circular Housing
  • Warranty
  • Yes
  • Drive Type
  • Direct or Belt Drive
  • Bearing Type
  • Ball / Roller Bearings
  • Mounting
  • Base Frame Mounted
  • Color
  • As per Customer Requirement
  • Casing Material
  • Heavy Duty Steel (Epoxy Coated or Painted)
  • Customization
  • Available on Request
  • Application
  • Boiler Flue Gas/Industrial Ventilation
  • Impeller Type
  • Backward/Forward Curved Blades
  • Operating Temperature
  • Up to 350C
 

Boiler IDs Fan Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Payment Terms
  • Cash Advance (CA)
  • Supply Ability
  • 5 Units Per Month
  • Delivery Time
  • 5 Days
  • Main Domestic Market
  • All India
 

About Boiler IDs Fan

Our company is presenting superior quality Boiler ID Fan to extensively spread treasured patrons. This type of fan offers optimal performance by effectively eliminating flue gases from the furnaces as well as forcing the exhaust gases up the stack. The offered fan is well acknowledged in the national market for its super functionality, trouble-free performance, low power consumption, and longer operational life. It is designed and manufactured by skilled technocrats with the use of premium grade components and approved technology in line with industry standards. In addition, we offer this Boiler ID Fan to innumerable prestigious patrons at unbeatable prices.

Product Detail:

Motor Rating

1 - 2 HP

Voltage

220 - 415 V

Type

V-Belt Driven Units

Material

Cast Iron

Brand

Ventilair

Capacity

5000 - 250000 m3/hr

Fan Speed

720 rpm

Usage/Application

Industrial



Engineered for Versatile Industrial Applications

Our Boiler ID Fan is purpose-built for a variety of industrial scenarios, such as boiler flue gas extraction and facility ventilation. The fan's centrifugal, backward or forward curved blades optimize air movement, while the circular steel housing handles high-pressure demands and ensures durability, even under elevated temperatures up to 350C.


Customizable to Meet Specific Needs

Clients can request various customizations, including air volume, power capacity, blade material (mild steel or stainless steel), drive type, speed, and even exterior color. Whether you need direct or belt drive, single or double revolution, or specific mounting and installation requirements, we offer configurations tailored to your unique operational parameters.


Reliable Performance and Long-Term Support

Designed for longevity and efficiency, our ID fans come epoxy coated or painted for superior corrosion resistance. They feature ball or roller bearings for reliable operation and reduced maintenance. Backed by a comprehensive warranty, these fans are supported by expert after-sales services, ensuring minimal downtime and continued smooth performance.

FAQ's of Boiler IDs Fan:


Q: How do I select the appropriate impeller type for my Boiler ID Fan application?

A: Selecting either backward or forward curved blades depends on your process needs; backward curved impellers are typically used for higher efficiency and handling higher pressures, while forward curved blades are ideal for low-pressure, high-volume applications. Consult with our engineering team to determine the optimal choice for your boiler or ventilation requirements.

Q: What is the installation process for these floor-mounted Boiler ID Fans?

A: The fan comes base frame mounted for easy installation on solid floors. Our service team can assist with guidance or onsite installation, ensuring proper alignment, electrical connections (415V), and integration into your existing system for peak performance.

Q: When should maintenance be performed on the ID fan bearings?

A: Regular maintenance is recommended based on operating hours and ambient conditions. Ball and roller bearings should be checked at intervals specified in the manual, with lubrication and inspections to prevent premature wear, ensuring ongoing efficient operation.

Q: Where can these fans be used besides boiler flue gas extraction?

A: These fans are suitable for a broad array of industrial ventilation tasks, including dust extraction, HVAC systems, and general exhaust in factories, process plants, and similar settings requiring robust airflow control at elevated temperatures.

Q: What customization options are available for the Boiler ID Fan?

A: Customization is available for airflow (2,000-40,000 m3/hr), power rating (3-150 kW), blade and casing materials, drive type (direct or belt), color, speed, and air pressure (100-2,000 mmWG). Share your specifications and our team will provide a custom-tailored solution.

Q: How does using a heavy-duty epoxy coated or painted steel casing benefit my operation?

A: Epoxy coatings or industrial paint protect the steel casing from corrosion, chemicals, and harsh environmental conditions, thus extending the life of the fan and minimizing maintenance costs, especially in demanding industrial environments.

Q: What warranty and after-sales services are included with the Boiler ID Fans?

A: All fans come with a manufacturer's warranty covering defects. We provide comprehensive support that includes technical consultation, spares, and service, ensuring quick resolution of any operational issue.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email



Back to top